열교방지 디테일이 적용된 현관문의 결로방지 성능평가
남중우, 원종서 · 한국생태환경건축학회 학술발표대회 논문집 · 2011
It is necessary to improve thermal performance of building skin for energy reduction in buildings. Generally, the front door facing outside directly or indirectly effects on the energy performance of buildings. The size of market related to a high performance door is increasing but it doesn't mean that the high-insulation door should have high condensation resistance performance. And recently the door with performance of preventing condensation and thermal insulation has been increased demand. In this paper, thermal performance of the door applied details of reducing thermal bridge was analyzed. The final conclusion through mock-up experiments is as follows. The surface temperature of the door has risen 2 degrees when details of preventing heat-bridge was applied. The temperature different ratio of the door of reduced thermal bridge was 0.9 lower than an existing door's.
Cited by 0 works.