ИССЛЕДОВАНИЕ СОСТАВА ОСТАТОЧНОГО И ПЛАЗМООБРАЗУЮЩЕГО ГАЗОВ В КАМЕРЕ УСТАНОВКИ ВАКУУМНОГО НАПЫЛЕНИЯ
A. E. Miheev, Харламов Валерий Анатольевич, С. Д. Крючек et al. · CyberLeninK (CyberLeninka) · 2013
2 JSC Information Satellite Systems named after academician M. F. Reshetnev 52 Lenin st., Zhelenogorsk, Krasnoyarsk region, 662972, Russia. Е-mail: vah@iss-reshetnev.ru With the help of a quadrupole mass spectrometer the authors study the composition of the residual gas in a vacuum chamber installation ARM NTP in the preparation of equipment for mining technology radio-reflective magnetron sput- tering coating. It is shown that at filling the chamber with pure argon the plasma gas may contain up to 0.3 % of resid- ual impurities from the gas chamber, including water and 0.02 % oxygen. The high content of carbon-containing gases shows the presence of residues of the solvents used, sorbed in rubber seals, equipment and gaps in other parts of the camera. To reduce the contamination of plasma-forming chamber atmosphere and to improve the purity of the composi- tion and properties of the coatings the additional cleaning and degassing chamber surfaces of residual moisture and carbon-containing compounds are required. To ensure the minimum contamination of the sprayed coating it is neces- sary to take measures for thorough cleaning and degassing of the chamber surfaces from residual moisture and carbon- containing compounds.
Cited by 0 works.