베이스 커브에 의한 콘택트렌즈 피팅 효과

최오목, 강명진 · 2000

The study investigated the effects of base curve radius on the fit of thin, mid-water contact lenses. It was found that central comeal curvature (as measured with the keratometer) was not predictive of the best fitting base curve. Lenses made from vifilcon A (the material used for Focus 1-2 weeks) tended to be most successful. When fit with the 8.4mm lens. For most eyes, fitting a f1atter vifilcon lens led to greater decentration, decreased comfort, and no increase in lens movement. The focus 1 - 2 weeks 8.4mm lens was found to provide on “ optimal fit in over 60% of eyes tested and a fit of “good or “better in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore. differemt products may require different base cuπes to best fit the same patient. This was true even when water content. diameter. and center thickness were approximately the same.

Cited by 0 works.