전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구

김민국, 전양근 · 한국물환경학회지 · 2005

The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is 67.1 ㎥/day. When the TMP and backwashing pressure was 0.85 ㎏/㎠ and 1.10 ㎏/㎠, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.