발사체 비행 화재안전 시스템 시제품 개발 시험 분석
고주용, 오택현, 이준호 · 한국추진공학회 학술대회논문집 · 2016
Analysis on the test result of fire prevention system development model that is applied to prevent fire/explosion inside the compartment of launch vehicle during the flight was carried out. Considered system was for the KSLV-II and the only different part is high pressure storage tank. The main purpose of this test is to check the characteristics of charging and discharging the gas storage tank. The leakage of the system during charging and maintaining the pressure was inspected and selected orifice was also checked through the test. As a result, the system charging and discharging processes were well performed. The pressure of gas storage tank whose volume is 0.04 ㎥ remains about 0.1 MPa after 90 seconds from pyro valve ignition. Also, the pressure and temperature at the inlet position of manifold just after the pyro valve are maximum 5.0 MPa and minimum –46.2 ℃.