고온고압 공기가열기 구조해석 연구

김정욱, 현동기, 박상훈 · 한국추진공학회 학술대회논문집 · 2016

The vitiated air heater is one of test facilities used for the purpose of supplying high temperature and high pressure air. Gases such as natural gas, oxygen, and air injected separately are combusted at its combustor chamber with the maximum pressure of 40 bar, and therefore it must be properly designed to prevent destruction and deformation. One of significant design characteristics is that it should be stable structurally at conditions of high temperatures and high pressures. The theoretical analysis with the use of ASME method is done to assess its structural stabilities. The present work finds that our design of the heater is acceptable for its experimental tests pneumatically and hydro-statically and its actual operations.

Cited by 0 works.