Информационно-измерительная система контроля частоты вращения ротора турбоагрегата стартового двигателя
Ляшенко Антон Валерьевич · CyberLeninK (CyberLeninka) · 2016
Background. Data-measuring systems and controlling systems of emergency protection deal with one of the most important goals while firing a launch vehicle, that is to measure rotary speed (RPM) of turbogenerator set in the boost rocket motor with subsequent transmission of actuating signal into the controls. This paper objective includes theoretical underpinning and experimental research of a noise-immune data-measuring system for speed of rotation control characterized by high reliability and high measurement accuracy. Materials and methods. Data-measuring system, proving one transducer operation, consists of two independent channels for signal processing, mirrored windings of variable inductance speed-of-rotation transducer, based on two 1887 ВЕ 1У microprocessor control units. Each processing channel deals with output frequency measurement, corresponding winding intactness control and output analog signal generation, pro rata with speed of rotation. Digital interface RS 485 is implemented in the first microprocessor control unit, which transfers data from the second channel into RS 485 interface after reading these data out of the second channel microprocessor control unit through serial interface SPI connecting both units. Results. The special features of the information-measuring system construction to control the rotor speed of rotation in turbo generator booster engine with inductance transducers are presented. The functional circuit of one of dual channels of the system, based on made in Russia microcontroller, and circuit performances are described. Signal processing methods providing higher noise immunity and reliability are emphasized. Periodic and impulse noises influence on measurement results is shown. Advantages and disadvantages of previously known noise immunity methods are estimated. It is offered to use amplitude and temporal discrimination methods to increase noise immunity. Conclusions. Following the outlined in this paper methods for enhancing noise immunity of the data-measuring system, it’s been possible to obtain the reduced error of frequency measurement more than ±0,1 % for the digital output, and not more than ±0,2 % for the analog output, when the frequency range is from 10 to 20000 Hz, transducer output signal is not less than 60 mV, and ratio “signal/noise” is more than two.
Cited by 0 works.