열감지 형광체와 인광 감쇄상수법을 이용한 고온 평판의 온도장 측정 기술에 관한 연구

이승재, 김현동, 지호성 et al. · 대한기계학회 춘추학술대회 · 2013

Thermographic phosphor thermometry was used to measure the temperature field of a hot plate. The manganese-activated magnesium fluorogermanate(Mg4FGeO6:Mn) was used as a thermographic phosphor to measure high temperatures (> 300 °C) on a surface using an optical method. Mg4FGeO6:Mn was coated on an aluminum plate with a HPC binder and placed on a hot plate, which could be controlled up to 550 °C. A pulsed UV-LED light source with a 385 nm wavelength to excite Mg4FGeO6:Mn was adopted for the lifetime-based measurement. A CMOS high speed camera (Photron Fastcam SA1.1) was used to acquire the images, and the surface temperature of the aluminum plate was monitored using K type thermocouples. A 655 nm band-pass filter was installed on a 50mm lens to filter the whole light except for the luminescence light. Decay constant analysis was applied to analyze the temperature field, and the decay constant was calculated from the measured phosphorescence images using the MATLAB program. The pulse frequency of UV-LED was 10 Hz, and the frame rate of the high speed camera was 4000 fps. After starting the impinging air jet cooling, the images were obtained for 5.4 seconds. According to the result, the hot plate temperature was decreased from 500 °C to 260 °C after starting oblique impinging air jet cooling and the 2D temperature field was visualized quantitatively.