직류 케이블의 절연진단에 관한 연구
박서준, 김선재, 왕국명 et al. · 한국철도학회 학술발표대회논문집 · 2016
A short-circuit fault occurs frequently due to the insulation deterioration of cable. Researches on the insulation diagnosis of cable used in AC power system have been well carried out. However, few investigations have been conducted for cable used in DC power system such as the electric railway system. Therefore, this paper described the insulation diagnosis techniques for cable used in DC railway vehicles with rated voltage of 1,500V. The insulation resistance method generally used and the partial discharge (PD) method that can detect small defect at its early stage were compared. The insulation resistance was measured by applying up to 5,000V to the high voltage cable. PD were analyzed in terms of pulse magnitude, counts, and T-F map.
Cited by 0 works.