연소 전 고체 추진기관의 내부 온도변화 특성에 관한 실험적 연구
송기혁, 강윤구, 구송회 · 한국추진공학회 학술대회논문집 · 2016
Ground combustion test is generally implemented to verify the performance of the motor on the three different operation temperatures(-40, 20, 60℃). The internal temperature of the motor is adjusted to operation temperature by temperature chamber, and the motor is moved out to test facility. After rapid setting, the motor is tested for combustion. In this process, heat loss or heat gain may happen and the long exposure time at outside can cause unintended results. This paper shows internal temperature characteristics of solid propulsion motor using HTPB propellant before combustion.