도시철도차량 객실 열적 쾌적성 향상을 위한 공조기 설계인자 형상 개선에 관한 연구

이윤휘, 우이완, 구정환 et al. · 한국철도학회 학술발표대회논문집 · 2016

This study, to improve the imbalance of the indoor air temperature distribution during operating the air conditioner of urban railway car, we test and consider the indoor temperature environment by changing the shape of vane and slot hole for cooling unit. In existing cooling system, there is the problem that temperature difference between central and end in car is 3 to 4℃ because of a flow deflection to end of car. To resolve this problem, as designing the new car for Busan 1 - Line, we adopted the additional vane in fan-outlet for evaporator of air conditioner and changed the shape of slot hole, to vertical shape and narrow area from horizontal shape and wide area. As a result of measuring the indoor air temperature distribution in modifying system, we confirmed that the indoor temperature environment is below 1℃ at all times.

Cited by 0 works.