가변안내깃 설치각이 다단 축류압축기 성능에 미치는 영향
박준영, 서정민, 임형수 et al. · 한국추진공학회 학술대회논문집 · 2016
Generally the variable guide vane is used to secure the sufficient operating point in the off-design condition. In this study the inlet guide vane, 1 st and 2 nd stators in a multi-stage axial compressor are movable to obtain the operating range. So the effects of variable guide vane setting angle on the performance of 2.5 stage axial compressor were investigated at 70 % and 90 % conditions of nominal rotating speed in this paper. The steady-state and unsteady numerical analyses were conducted at each operating condition. The performance map lost efficiency and flow fields were compared.
Cited by 0 works.