논문 : 하수처리시설 총 유기탄소 분포 및 유기물질간 상관관계 분석

조영범, 오용걸, 신동철 et al. · 한국환경분석학회지 · 2014

This study was conducted to compare the behavior of total organic carbon among biological sewage treatment processes and analyze correlations between organic matters in the influent and effluent of sewage treatment plants (STP). Target STPs selected for this study were four plants where representative processes were applied according to the processing system. The treatment processes used in these plants included 4-stage biological nutrient removal (4-stage BNR), bio ceramic sequencing batch reactor (BCS), denitrification and phosphorus removal (DeNiPho), and membrane bio-reactor (MBR). The TOC removal rates of the four plants averaged 86.9%, lower than their COD and BOD removal efficiencies, but the TOC concentrations in their effluent were steady (no higher than 10 mg/L). In the simple correlation analysis, TOC showed the highest correlations with SBOD5(r=0.989) and TCODMn (r=0.971) in the influent and with SCODMn(r=0.996) in the effluent, which indicates that TOC can replace COD as an organic indicator. According to the principal component analysis (PCA), three components were extracted from PCA A between organic matters in the influent and effluent. For the influent, the analysis result showed that the first component had high positive correlations with TOC, DOC, TCODCr, SCODCr, TBOD5, and SBOD5. Its variance was 59.1% among all principal components (PCs). The PCA of the effluent suggested that PC 1, PC 2 and PC 3 accounted for 44%, 35% and 21% of the total variances, respectively. The first component had high positive correlations with POC, TSS, VSS, T-N, and sT-N.

Cited by 0 works.