고온밸브 비정상상태 해석 기법에 관한 연구

이경욱, 허선욱, 권세진 et al. · 한국추진공학회 학술대회논문집 · 2016

Numerical simulations of the hot gas valve have been conducted in order to establish the transient analysis method. Time step size and iteration were chosen for economical analysis. Transient analysis has been conducted by increasing the time step size throughout the four sections considering the operating time of the hot gas valve. Time step size was increased when quantitative result reached within 3% difference in each section. Flow field, pressure field, temperature field in flow area were reached steady state with within 3% difference at 8 ms, 100 ms and 5.5 sec respectively. Flow field, pressure field, temperature field in flow area were reached steady state at 10 sec from operating time of the hot gas valve, however, there are about 7% difference in the temperature field in solid area.

Cited by 0 works.