Толщина сетчатки в макулярной области в норме в молодом возрасте

Мухамадеев Руслан Алекович · Вестник Оренбургского государственного университета · 2015

The purpose of the study was to obtain normative parameters retinal thickness in the macular region. The thickness of the retina was measured at 76 ophthalmological healthy volunteers using an optical coherence tomograph Cirrus HD-OCT 5000. Used a standard protocol Macula Cube 512х128. For the center of the macula (within 1 mm) average thickness of the retina was 249,41±15,50 μm (220-284 μm). Macula (within 1 to 3 mm): upper 324,16±11,72 μm (296-347 μm), nasal -323,03±11,90 μm (296-348 μm), lower 320,31±10,78 μm (293-339 μm), temporal -310,41±13,57 μm (265-344 μm). For a perimacular region (within 3-6 mm): upper -279,79±10,97 μm (250-305 μm), nasal 295,49±10,97 μm (273-319 μm), lower -269,20±9,86 μm (248-295 μm), temporal 263,99±10,24 μm (242-287 μm). The average thickness of the retina was 281,66±9,34 μm (259-298 μm), the average volume of the retina within the investigated region 10,14±0,34 mm3 (9,3-10,7 mm3). There were significant differences between the thickness of the retina in the central sectors and in nasal and temporal sectorsperimacular region between men and women: women have lower value. These indicators can be used as reference values to assess the reduction in the thickness of the retina as a result of various degenerative processes, or to determine the degree of increase in retinal thickness at its swelling.

Cited by 0 works.

Authors