신 기후변화 체제 대응을 위한 온실 난방설비 개선 방안 고찰
윤시원, 이찬규, 장기창 et al. · 대한설비공학회 2016년도 하계학술발표대회 · 2016
In general, large amount of energy is needed to maintain the adequate environment of crops especially during winter and night time with regards to facility horticulture. That is, heating cost account for 30 to 40 percent among many operating cost. Also, back in 2015, Korea announced that it will decrease greenhouse gas emissions by 37 percent compared to BAU by 2030. The fact that great portion of horticulture facility depends on fossil fuels such as coal or duty-free oil prevents from not only enhancing of revenues of the farmers but also achieving the greenhouse emission target. To deal with current situations, an improvement of heating facilities in horticulture is necessary. This paper presents a improvement of paprika greenhouse heating facilities according to the pipe diameter and fin installation based on 2D CFD analysis. The results showed that the pipe diameter and implementation of fin was effective in terms of heat transfer rate to the nutrient bed which enabled lower temperature of heating water supply. Finally the potential greenhouse gas emission in heat pump system was calculated considering abovementioned two parameters.
Cited by 0 works.