Results of thermal design of construction elements of the multizone combustion chamber intended for utilization of associated petroleum gas are presented. The temperature of flame tube is defined by method of successive approximations of heat-balance equation when operating the steady-state conditions. Flame tube is heated by reason of convective and radiant heat fluxes from combustion products. Thus the part of heat from flame tube is spent for heating of secondary air in annular gap between flame tube and casing (convective heat exchange) and for casing heating (radiant heat exchange). In turn heat from a casing is spent also for heating of secondary air and for losses in environment which are insignificant. Heating of secondary air in annular gap is insignificant and makes 1–2 % from heat exchange of flame tube. Convective heat fluxes are determined by known criteria ratios. Calculation of radiant heat fluxes is executed by new empirical dependences obtained in development test at Central Institute of Aviation Motorbuilding. The maximum temperature of flame tube is observed in the field of its adjunction to a burner block at zone of burning. The maximum temperature of casing is observed at exit of combustion chamber. The analysis of results of the thermal calculations which have been carried out separately for each zone of combustion chamber allow to make recommendations about use of constructional materials.