Качество освещения и охрана труда

Воронин Вячеслав Андреевич, Долгопол Татьяна Леонидовна · Вестник Кузбасского государственного технического университета · 2016

The main idea of the paper is focusing on the problems of ensuring the required level of illumination quality in public buildings. The paper evaluated the influence of reflection coefficients of room surface, color temperature of lamps, candlepower distribution of lamps on quality and quantity indices of illumination. It begins with the lighting audit of different rooms of KuzSTU, then the unified glare raiting and illumination ripple factor are analyzed. According to the results, the reflection coefficients of wall and floor has a negligible impact on the illumination ripples. Increasing of the reflected luminous flux reduces the unified glare raiting. Greater influence on the illumination quality has the color temperature of lamps and candlepower distribution of lamps.

Cited by 0 works.

Authors