О влиянии фрагментации контактных пятен на сопротивление сильноточных электрических контактов
О. М. Павлейно · Современные проблемы науки и образования · 2014
The work uses the solutions of several numerical problems with the help of ANSYS software to estimate the effect of the conducting surface structure of high-current electric contacts upon their performance. In particular, it analyzes the effect of imhomogeneities, caused by undulation, upon the distribution of potential in the contact area and, hence, the magnitude of contact resistance. The region of the current constriction to contact spots is separated into the near and far zones as to the degree of the fragmentation effect upon the said distributions, and the zones boundaries are found. It is shown what imhomogeneities parameters allow calculating the contact resistance in the unfragmented contact spot approximation without a significant loss of accuracy. This enables reducing the numerical simulation procedure, since consideration of contact spot fragmentation always results in an essential complexity of the calculation models and the growing resource intensity of the problems being solved.
Cited by 0 works.