Диагностирование контактной системы регулятора напряжения под нагрузкой
Georgi M. Mikheev, Каландаров Хусейнджон Умарович, Иванова Татьяна Георгиевна · Электротехнические и информационные комплексы и системы · 2015
In the article the diagnostics of on-load tap changer contact system of power transformers with opening the contactor tank and draining the transformer oil is considered. An algorithm for diagnosing of high-speed three-phase voltage regulator under the load with current-limiting resistors regarding to switching devices produced in Bulgaria of RS series. Such devices are joined to the high-voltage power transformer windings connected in star scheme. The algorithm given makes it possible to determine the diagnosis performance of the three-phase voltage regulators under load of RL series. In the diagnosing process current waveforms of the switching device contactor contacts are collected. Basing on the current oscillograms of the contact system the correct order of contactor contacts alternation is determined. The algorithm is based on comparison the data of the measured values of the currents and time of the switching process with the standard waveform specified in the control voltage under load passport. Each measurement is stored in a database of digital oscilloscope. Current waveforms analysis is carrying out on three sections. The first and the third section represent active time of left and right shoulders of the on-load tap changer contactor contacts respectively. The second section represent active time of left and right shoulders of the on-load tap changer contactor and is so-called scheme of contact system bridge. Besides checking the correct alternation of the contactor contacts switching, the algorithm developed can determine the break in the circuit with current limiting resistors of the left and right contactor shoulders. At the time of diagnosis in the second section (the bridge scheme) the break of the branch with the current-limiting resistors is found out. Since diagnosed fast voltage regulator under the load with current-limiting resistors is performed in three-phase version, checking the switching device contactor contacts is carrying out for all three phases of the contactor simultaneously. After the end of the algorithm in all three sections of the circuit of voltage regulator under the load contact system of PC series checking the total time of switching the contactor contacts is carrying out with the conditions specified in the standard waveform. Further the switching device re-diagnostics request is displayed. If there is no need for this the algorithm ends.
Cited by 0 works.