비닐하우스용 히트펌프시스템의 성능평가에 관한 연구

송뢰, 박윤철, 고광수 et al. · 대한설비공학회 2016년도 하계학술발표대회 · 2016

At this experimental study we evaluated the heating performance of hybrid heat pump system. This system is installed at a 100㎡ greenhouse that located in jocheon-ri of Jeju Province. The hybrid heat pump system was consisted with two heat storage tanks, solar collector, heat exchanger, fan coil unit, temperature expansion valve, 4-way valve and compressor. Working refrigerant was R-410a in the system. The hybrid heat pump system using outdoor source and heat storage tank source. And the outdoor source is mainly studied in this paper. When the set temperature was fixed at 10.9℃ outside of the greenhouse, the COP is 13, and the COP of the system increased up to 15 incase of 8.1℃ of outside temperature.