다차원 전열해석을 통한 공정간소형 외단열 공법의 열성능 개선효과에 관한 연구
이상헌, 최지혜, 백호 · 대한건축학회 논문집 - 계획계 · 2016
The aim of this study is the evaluation on effectiveness of the thermal performance improvement for concurrent EIFS. The result of this study as follows : 1) Concurrent EIFS was superior economics compared existing EIFS. 2) Linear thermal transmittance analysis results that concurrent EIFS was improved an average of about 56% compared to internal isulation system. 3) Equivalent thermal transmittance analysis results that although there was no change in concurrent EIFS, internal insulation system was reduced approximately 3 times. 4) Surface condensation analysis results that concurrent EIFS had not condensation occurs. However, internal insulation system had condensation occurs in the front balcony and the rear kitchen balcony.