활성슬러지공정 최적화를 위한 호흡율측정에 기초한 제어 전략
허남효, 강호, 김창원 et al. · 대한환경공학회 학술발표논문집 · 1999
Recently, various control strategies for the activated sludge process based on respirometry were introduced by the IAWQ Task Group on Respirometry in its Scientific and Technical Report (STR). Respirometry is the measurement of the oxygen consumption rate of activated sludge under well defined experimental conditions. Because oxygen consumption is directly associated with both growth and substrate removal, respirometry is a useful technique for controlling and operating of the activated sludge process. This paper is based on two different respiration rate, which can be measurement with the substrate-limiting and excess of substrate condition. The actual respiration rate of activated sludge is dependent on the substrate concentration and reflects the loading of the plant, and the maximum respiration rate is independent of the substrate concentration. Literature shows that measuring actual respiration rate and maximum respiration rate can be useful for loading control, toxicity dection, estimation of active biomass on the activated sludge. In this study, actual and maximum specific respiration rate were used as control parameter for stable sludge loading rate and detection of toxicity, respectively.