Регулирование процесса теплообмена в зоне контакта малонагруженных соединений

Попов Виктор Михайлович, Новиков Алексей Петрович, О. Л. Ерин · CyberLeninK (CyberLeninka) · 2012

Many thermally-stressed technical systems have the plug connections. With the passage of heat flows through these connections through the discrete contact of surfaces on their way appear., the so-called contact thermal resistance (CTR) Operating conditions of such technical systems require, in some cases reduce of CTR, while in others its increase. In this paper we study experimentally technological method to increase of CTR, ie increase in heat-insulating properties of the transition zone. On installation for the study of contact heat exchange contact pairs were tested of brass, brand L80, and aluminum alloy D16T with contact surfaces treated by grinding. In the contact zone filler were introduced in the form of pads from asbestos, mica, teflon and fiberglass. It was found that CTR for the compounds with fillers is significantly higher than at direct contact of surfaces. Temperature increase in a contact zone reduces CTR. For compounds with fillers in the contact pair from more heat-conducting alloy D16T in comparison with a pair of brass, L80, CTR is significantly lower. Good effect to increase CTR the operation on putting of powder aggregates in the contact zone provides. Increase in the size of input powder particles leads to an increase in CTR, and the increase in the number of particles per unit of contact area is accompanied by a decrease in CTR. The results obtained in the process of research allow us to regulate the process of heat transfer in composite systems.