Анализ адаптационной комфортности различных конструкций эндопротезов тазобедренного сустава
Ю. В. Акулич, Р. М. Подгаец, Скрябин Владимир Леонидович et al. · Российский журнал биомеханики · 2005
The three-dimensional elastic stress and deformation state in the human femur after the hip joint total replacement has been studied by computer simulation. The linearity of the stress-deformation curve under the physiological load was established by experiment in vitro. The transversal isotropy and non-homogeneity of the bone elastic properties were taken into account. The efforts of femoral muscles and the pelvic bone reaction force were calculated from the condition of minimal sum of modules of the muscular forces. The condition of ideal contact was assumed at the boundary between the bone and the stem of metal endoprosthesis; this condition is feasible when the bone grows into the pores in metal. The stress and deformation state of the femur immediately before the implant installation has been accepted to be natural, i.e. zero. It has been assumed that the form of the femoral channel follows the contour of implants stem, i.e. there are no residual stresses and deformations in the bone after the operation. The unilateral (along the osteon axis) model of the compact bone tissue internal remodeling allowed us to predict bone adaptation under the body weight and muscular efforts during the resumption of walking after the surgical intervention. The kinetic equation of the adaptive remodeling model establishes linear connection between the change rate of the Haversian canal radius and the deformational adaptation stimulus; the proportionality factor in this equation depends on the bone cells activity. The balance type equations used in the model are consistent with the principles of adaptive changes in human organism. The process of adaptive changes in bone tissue porosity and elastic modulus has been studied by the computer simulation of the cylindrical specimens cut from the femur diaphysis near the implants stem; the obtained curves are of monotonous character. The time of these curves transition to a steady level is determined largely by their rate of change at the initial time instant. This fact allowed us to formulate the adaptive comfortableness criterion of the implants stem design. This criterion permits to estimate quantitatively the rate of porosity rise in the femoral cortex induced by the redistribution of the physiological load carried by the bone tissue after the implant installation. The results of such estimation for three most commonly used implant designs are presented.
Cited by 0 works.