양안굴절검사에서 구면-원주굴절력의 변화

박상배, 김광배, 김영훈 et al. · 대한시과학회지 · 2006

Refractive error is a common cause of blurred vision and asthenopia. Several different tests for the measurement of sphere and astigmatism have been described in the literature, but there are no studies that have compared the results of monocular refraction and binocular refraction in Korea. The results of two refraction tests performed on 115 patients were compared. Binocular refraction included the Jackson cross cylinder(JCC) and the Humphriss immediate contrast(HIC) test with pantoscopic tilt of 10 degrees, utilized distance targets. The mean refractive power difference between monocular refraction and binocular refraction with pantoscopic tilt tests were statically different(p < 0.05) ‘ Sphero cylindrical refractive power was decreased in binocular HIC test. The change of cylindrical refractive power was O.l3:!:0.33D. The eyes having with the rule astigmatism were most affected by interpalpebral fissure size(p < 0.01). And the interpalpabral fissure size was the most magnificat factor influencing the change of astigmatism in binocular refraction(p < 0.01). And there was negative correlation between the fissure size and the cylindrical refractive power with W -T 묘 drift(p < 0.01). These results suggested that on theoretical and clinical grounds, a binocular refraction with pantoscopic tilt method for sphero-cylindrical power and axis determination, such as the HIC, is advisable for the patient with cyclophorias and significant amounts of astigmatism.

Cited by 0 works.

Authors