РАЗРАБОТКА ПРИНЦИПА И МАТЕМАТИЧЕСКОЙ МОДЕЛИ СОКРАЩЕНИЯ ИНТЕГРАЛЬНЫХ ЗАТРАТ В ЦИЛИНДРИЧЕСКИЕ, ВЕРТИКАЛЬНО УСТАНОВЛЕННЫЕ, ФИЛЬТРУЮЩИЕ УСТРОЙСТВА

ALEKSANDR P. USACHEV, Шурайц Александр Лазеревич, D. Salin et al. · 2016

The minimum cost in a cylindrical filter high bandwidth are achieved when the ratio of the height of the housing to a diameter equal to 4.5. In this case, the height of the cylindrical filtering devices in the form of molded products is 65% of the height of the filter housing that will lead to an increase in the size of the room required for its extraction and consumption of thermal energy for heating the additional portion of the premises distributing unit. In order to reduce the consumption of materials and total cost in the location of the cylindrical filtering devices, according to the patent № RU 158000 U1 with priority from 16.12.2014, proposed to install several filtration devices placed on one another. The article proposes a mathematical model to determine the optimal number of filtering devices, which correspond to minimal additional costs in them and the room to accommodate them. It is proved that the control parameter of the proposed mathematical model is the number of the filtering devices because it expresses a contrary influence on the value of capital investments and operating costs in their production, installation and dismantling, on the one hand, and on the other hand in the segment of space that is needed to extract the filter devices. The results of calculations showed that, for example, for a filter with the diameter of inlet and outlet pipes 350 mm, located in the gas control unit, the optimal number of filter device is three pieces.

Cited by 0 works.