Определение бериллия и никеля в крови атомно-абсорбционным методом с электротермической атомизацией и зеемановской модуляционной поляризационной коррекцией фона

Иваненко Наталья Борисовна, А. А. Иваненко, Носова Елена Борисовна et al. · Вестник Санкт-Петербургского университета. Серия 4. Физика. Химия · 2011

A technique was developed for whole blood beryllium and nickel determination based on graphite furnace atomic absorption spectrometry with Zeeman high-frequency polarization modulation background correction. Be determination was performed using graphite furnaces with integrated Lvov platforms and without modifiers. For Ni determination 2 % ammonium nitrate matrix modifier and wall atomization were used. Certified reference material: SeronormTM Trace Elements Whole Blood L-3 with known Be and Ni content was analyzed for technique validation. Dynamic range was 0,5-25 μg/L and 1-25 μg/L for Be and Ni respectfully. Precision (RSD) was less than 12 %. The technique developed was applied for real blood sample analysis. Be was measured in the blood of rats exposed to Be salts. Ni was determined in the blood of 38 electro welders and 24 persons of the control group.