Использование Фурье-спектроскопии высокого разрешения для исследования газовых смесей и пробы атмосферного воздуха

Французова Инна Сергеевна, Поберовский Анатолий Васильевич, Юрий Михайлович Тимофеев et al. · Вестник Санкт-Петербургского университета. Серия 4. Физика. Химия · 2015

This work illustrates the application of high-resolution Fourier spectroscopy for the research of gas mixtures by the example of a standard mixture of CO + N 2 and air sample. The determination of the components of the calibrated gas mixture and ground-level concentrations of atmospheric trace gases (ATG) was based on the analysis of the absorption spectra measured by a Fourier spectrometer. By means of numerical simulation an error estimation of the experiment was carried out. As a result of three independent experiments, the data of the concentration of calibrated gas mixture CO + N 2 shown in this paper was obtained. An analysis of the air sample taken on the ground-level was also made. These calculations show that the margin of error of IR spectroscopic measurements of ground-level concentrations of CO, CH 4, N 2 O, CO 2 and H 2 O is 1-4% in different spectral ranges.

Cited by 0 works.