К вопросу исследования условий эксплуатации и внедрения некоторых образцов кабелей в газотурбинных установках АО «Мотор Сич»

Владимир Максимович Снигирев, Алексей Иванович Афанасьев, К. В. Дудник et al. · Восточно-Европейский журнал передовых технологий · 2014

The study of temperature conditions of thermometering cable runs of ground-based gas turbine plants in order to determine maximum temperatures during continuous operation is given in the paper. Plants include gas turbine drive (GTD), in a compartment of which it is necessary to lay cable lines, where during the rated power operation, air temperature can reach up to 100 °C (with places of local overheating above 200 °C). Therefore, protection of cable lines from high temperatures is an urgent task.Testing a number of cables and thermal-insulating pipes for the stated temperature by manufacturers of these products is aimed at recommending the best of them for use in gas turbine plants.Tests have shown that thermal-insulating tubes of company «SilvynHiprojacket» and «AgrotubeC-HTS», without their internal blowing do not have the necessary thermal-insulating properties since the temperature inside and outside the tested tubes differed by a maximum of 2 °C. Therefore, cables Olflexclassic 110 and 180OlflexHeat sihf, which for a long time can withstand temperatures up to 120 °C, at ambient temperature in the GTD compartment from +20 °C to +55 °C, which is supported by the ACS are recommended for cable lines of gas turbine plants.