Экспериментально-клиническое обоснование применения дозированной дермотензии в первую фазу раневого процесса

Vladimir Viktorovich Beschastnov, Н Ю Орлинская, М Н Кудыкин · Electronic archive of the library (Vitebsk State Medical University) · 2012

ÄÎÇÈÐÎÂÀÍÍÎÉ ÄÅÐÌÎÒÅÍÇÈÈ Â ÏÅÐÂÓÞ ÔÀÇÓ ÐÀÍÅÂÎÃÎ ÏÐÎÖÅÑÑÀÃÁÎÓ ÂÏÎ «Íèæåãîðîäñêàÿ ãîñóäàðñòâåííàÿ ìåäèöèíñêàÿ àêàäåìèÿ» Ìèíçäðàâñîöðàçâèòèÿ Ðîññèè, Ðîññèéñêàÿ Ôåäåðàöèÿ Öåëü.Ñîêðàòèòü ñðîêè ëå÷åíèÿ ïàöèåíòîâ ñ îáøèðíûìè ãíîéíûìè ðàíàìè ìÿãêèõ òêàíåé ïóòåì ðàñøèðåíèÿ ïîêàçàíèé ê äîçèðîâàííîé ñïèöåâîé àïïàðàòíîé äåðìîòåíçèè.Ìàòåðèàë è ìåòîäû. ýêñïåðèìåíòå íà ìîäåëè èíôèöèðîâàííîé ðàíû ó êðûñ èçó÷àëîñü âëèÿíèå äîçèðîâàííîé äåðìîòåíçèè íà ìîðôîìåòðè÷åñêèå õàðàêòåðèñòèêè ñòðóêòóðíûõ êîìïîíåíòîâ ðàíû.Èçó÷àëè èçìåíåíèÿ, ïðîèñõîäÿùèå íà ðàññòîÿíèè îò ó÷àñòêà ðàñòÿæåíèÿ, íåïîñðåäñòâåííî â îáëàñòè ïåðâè÷íîãî ðàíåâîãî äåôåêòà.Ãèïîòåçà ñîñòîÿëà â òîì, ÷òî íàòÿæåíèå òêàíåé ïàðàâóëüíàðíîé îáëàñòè ïðèâîäèò ê ïðîäóêöèè ìåäèàòîðîâ âîñïàëåíèÿ, öèòîêèíîâ, ÷òî â ñâîþ î÷åðåäü âåäåò ê ñòèìóëÿöèè ðåïàðàòèâíîãî ïðîöåññà â îáëàñòè ðàíû.Êðèòåðèåì, ïîçâîëÿþùèì îöåíèòü ïðàâèëüíîñòü ãèïîòåçû, ÿâëÿëèñü ñêîðîñòü çàæèâëåíèÿ ðàíû, ñðîêè ýïèòåëèçàöèè. êëèíèêå â ïåðâóþ ôàçó ðàíåâîãî ïðîöåññà äîçèðîâàííàÿ ñïèöåâàÿ àïïàðàòíàÿ äåðìîòåíçèÿ ïðèìåíÿëàñü ó 12 ïàöèåíòîâ, òðàäèöèîííûé ìåòîä ëå÷åíèÿ ãíîéíîé ðàíû «ïîä ïîâÿçêîé» ó 18 ïàöèåíòîâ.Îáúåêòèâíûé êîíòðîëü ñîñòîÿíèÿ ìÿãêèõ òêàíåé ïðè âûïîëíåíèè ñïèöåâîé àïïàðàòíîé äåðìîòåíçèè îñóùåñòâëÿëè ñ èñïîëüçîâàíèåì ìåòîäà ëàçåðíîé äîïïëåðîâñêîé ôëîóìåòðèè.Ðåçóëüòàòû.Èññëåäîâàíèÿ, ïðîâåäåííûå íà ìîäåëè èíôèöèðîâàííîé ðàíû ó êðûñ, ïîêàçàëè, ÷òî äîçèðîâàííàÿ äåðìîòåíçèÿ ïàðàâóëüíàðíîé òêàíè ïîëîæèòåëüíî âëèÿåò íà êà÷åñòâåííûé ñîñòàâ òêàíè, îáðàçóþùåéñÿ ïðè çàæèâëåíèè èíôèöèðîâàííûõ ðàí, î ÷åì ñâèäåòåëüñòâóåò ñîîòíîøåíèå ãðàíóëÿöèîííîé òêàíè è ôèáðîáëàñòîâ, óñêîðåíèå ïðîöåññîâ î÷èùåíèÿ ðàíû è îáðàçîâàíèÿ ðóáöà. êëèíèêå, ïðè ïîìîùè äîçèðîâàííîé ñïèöåâîé àïïàðàòíîé äåðìîòåíçèè áûëè çàêðûòû ãíîéíûå ðàíû øèðèíîé îò 7 äî 16 ñì è ïîñëå íàëîæåíèÿ øâîâ ïîëó÷åíî çàæèâëåíèå ðàíû ïî òèïó ïåðâè÷íîãî íàòÿæåíèÿ ó 11 ïàöèåíòîâ èç 12.Çàêëþ÷åíèå.Èñïîëüçîâàíèå äîçèðîâàííîé ñïèöåâîé àïïàðàòíîé äåðìîòåíçèè äëÿ çàêðûòèÿ îáøèðíîé ãíîéíîé ðàíû â ïåðâóþ ôàçó ðàíåâîãî ïðîöåññà ðàñøèðÿåò ïîêàçàíèÿ ê ïðèìåíåíèþ àêòèâíîé õèðóð-ãè÷åñêîé òàêòèêè è ñîêðàùàåò ñðîêè ëå÷åíèÿ ïàöèåíòîâ äàííîé êàòåãîðèè. Êëþ÷åâûå ñëîâà: ðàíà, ðàíåâîé ïðîöåññ, ïåðâè÷íîå íàòÿæåíèå, äåðìîòåíçèÿObjectives.To shorten the treatment terms of patients with extensive purulent wounds of soft tissues by expanding indications for the dosed hardware apparatus dermotension. Methods.Influence of the dosed dermotension on the morphological characteristics of the structural wound components was studied in experiment on the model of the infected wound in rats.Changes occurring distantly from the area of tension were studied, directly in the area of the primary wound defect.Hypothesis was that tension of the paravulvar area tissues resulted in the production of inflammation mediators, cytokines and this in its turn led to the reparative process stimulation in the wound area.Criterion letting estimate the correctness of the hypothesis was the speed of wound healing and terms of epithelialization.Dosed hardware apparatus dermotension was applied in the clinic in 12 patients at the first stage of wound process; in 18 patients a traditional method of purulent wounds treatment "under dressing" was applied.Objective control of soft tissues state while applying hardware apparatus dermotension was carried out using the laser Doppler flowmetry method.Results.Investigations which were done on the model of the infected wound in rats show that dosed dermotension of the paravulvar tissue influences positively the tissue qualitative composition which is formed at infected wound healing; it is proved by the ratio of granulated tissue and fibroblasts, acceleration of the wound cleaning processes and scar forming.In the clinic, using the dosed hardware apparatus dermotension, purulent wounds from 7 up to 16 cm in width were closed and after suturing wound healing according to the type of primary tension was achieved in 11 out of 12 patients.Conclusions.Use of the dosed hardware apparatus dermotension to close extensive purulent wounds at the first stage of the wound process expands indications for application of active surgical tactics and it reduces terms of treatment of this category of patients.

Cited by 0 works. Open-access PDF

Authors