Measuring system of the batcher of bulks different from relay system with sensors of extreme situation by that it is in addition supplied with the electrometric sensor allowing to measure small deviations of weight on a tape of the weight conveyor by the linear sensor without inclusion of the watching system is considered. The condition of system depends on physicomechanical characteristics of the dosed mix components, on nature of giving by a material feeder on the weight conveyor. The best properties and bigger uniformity of supply of material, feeders with its smaller dispersion possess. The systematic error is function of the relation of mass of control to the set dose and correction coefficient of system. The correction coefficient is closer to unit, the less size of a systematic error, and near a control point it is almost equal to zero.