Влияние перепадов температуры окружающей среды на главное условие цифрового нивелира при наблюдениях за осадками фундаментов зданий и сооружений

Антон Викторович Никонов, Чешева Ирина Николаевна, Лифашина Галина Викторовна · Вестник СГУГиТ (Сибирского государственного университета геосистем и технологий) · 2016

In the process of surveying works geodetic level can suffer temperature influence of environment: when taking the device from the case, working in hot shop, giving reference point from indoor to outdoor position and in other cases. The paper gives the results of angle i change of digital geodetic level Trimble DiNi0.3 in sharp temperature shift from 16°С to 28°С. The surveying was conducted in summer and winter period: the angle i was multiply measured at first in laboratory, then in field conditions. It is stated, that in 1°С temperature change the angle change does not exceed 0.5ʹʹ. The application of digital geodetic level lets enlarge acceptable difference of station shoulders from 0,2–0,4 to 2,0 m.