송풍기 유량센서의 운용온도와 센서수명 영향성에 관한 연구

이공희, 윤의열, 전희호 et al. · 대한기계학회 춘추학술대회 · 2016

The normal state of blower which is used for cooling device is very important for the equipment system protection. For that reason, the electronic system is identifying the normal state of the blower by mounting the air flow sensor to the blowers internal duct. The air flow rate sensor of the mechanical type, there is a problem that is occasionally broken. This caused more of sensor fracture I the operating conditions of elevated ambient temperature. It is estimated that operational temperature is affected a air flow sensor life. In this paper, It was confirmed the effect of the sensor life according to an operational temperature through FSI(Fluid & Structure interaction) analysis. ANSYS Fluent and Mechanical tool was used for FSI analysis. The sensors stress value due to the air flow rate of the blower was calculated by performing a fluid analysis, and it analyzed the sensors fatigue life at the room temperature and elevated temperature using the S-N diagram. As the results, the higher the temperature was confirmed that the sensor life is low, the sensor life is improved by the lowering of the ambient temperature.

Cited by 0 works.