철도 선로변 적용 흡음형 태양광 방음벽 모듈 내부 공간에서의 열분포 실험
장용준, 류지민 · 한국철도학회 학술발표대회논문집 · 2016
Experiment is performed for temperature distribution analysis inside module of noise-absorbing solar soundproofing wall applicable to railway. The size of module is 1,960mm ⅹ 1,000mm ⅹ90mm (thickness). The front is equipped with solar cells of 66 and generate 300W. The reverse side is equipped with noise-absorbing material which absorb railway noise. The inner space between solar panel and noiseabsorbing material is empty to remove the accumulated heat due to the solar panel and is 48mm. The outside of module has 41 holes on each left and right side and 57 holes on each up and down side to discharge the heat accumulated inside module. The size of hole is 7mmⅹ20 mm. The front solar panel is heated to be 60℃ and the heat distribution inside module is investigated using thermocouple.
Cited by 0 works.