박스형 이중외피 창호의 환기구 조절에 따른 하절기 중공층 열환경 특성

송진희, 강소라, 임재한 et al. · 추계학술발표대회 · 2013

This study focused on evaluation on thermal environment inside a box-type double-skin window cavity (0.14m width) according to operation of vents and the inside venetian blind. For this purpose, the temperatures inside cavity were measured and analyzed with local weather conditions in the summer. The average and maximum temperature inside cavity in the opened-vent case were 1.9℃ and 6.2℃ lower than the temperatures in the closed-vent case. And the average and maximum temperature inside cavity with blinds operated case were 1.2℃ and 6.6℃ higher than them with blinds not operated. As the results, the ventilation efficiency inside the cavity can be improved by opening vents, but can be decreased by pulling down the blind inside cavity.