개방 포트 압력을 이용한 서보밸브 히스테리시스와 영점 진단에 관한 실험적 연구
김성동, 주별진, 윤소남 · 유공압건설기계학회 학술대회논문집 · 2016
The conventional technique to measure the hysteresis and null of servo valves is defined in ISO 10770-1 and it is based on load flow signal of the servo valve. A new technique based on the open control ports pressures is suggested in this study. The new measuring method was verified through a series of experiments. No hysteresis was observed between the spool displacement and the open control ports pressures; load pressure and each chamber pressure. Some hysteresis was observed between valve input and the pressures, which was found to be the same as those of load flow and spool displacement for the valve input. Using the port pressures are easier to measure the hysteresis and null than the load pressure or differential pressure between those two chamber pressures because the port pressures showed sharp edges.
Cited by 0 works.