미세유동을 위한 고정밀 압력펌프 설계 및 성능평가

안돈관, 손동진, Simon Song · 대한기계학회 춘추학술대회 · 2016

The precise control of flow rate is important to obtain accurate analysis results on a lab-on-a-chip. A most frequently used device is a syringe pump but it has a low precision and shows irregularities in flowrate due to the motor and traverse system. To improve this problem, we develop a pressure pump with a high precision flow control for microfluidic applications. The pump system actively regulates the pressure of a reservoir and monitors the flow rate in a real time. As a result, it shows a higher accuracy in controlling flow rate than a commercial syringe pump.

Cited by 0 works.

Authors