ДОСЛІДЖЕННЯ ВПЛИВУ ОПТИЧНИХ ХАРАКТЕРИСТИК ПІРОМЕТРІЇ ВИПРОМІНЮВАННЯ НА ПОХИБКИ ЛІНІЙНОЇ БАГАТОКОЛЬОРОВОЇ СИМЕТРИЧНО-ХВИЛЬОВОЇ ТЕРМОМЕТРІЇ
Леонид Жуков, Андрей Корниенко · Lighting Engineering & Power Engineering · 2016
The authors investigated influence of the optical characteristics of multicolor radiation pyrometry and thermometred objects on methodological errors of linear symmetrical-wave radiation pyrometry. They have determinate that even if significant deviations of the spectral distributions of emissivity from linear, the errors of the symmetrical-wave thermometry does not exceed 0,5% and can be further reduced by an optimum combination of the optical characteristics of radiation pyrometry. In the studied conditions of known errors of optical thermometry in 2,4 - 25,0 times higher than the error symmetrically-wave radiation pyrometry.
Cited by 0 works.