피동고압충수용 혼합형 안전주입탱크 내부 열전달 분석
김명준, Jae Min Kim, 류성욱 et al. · 대한기계학회 춘추학술대회 · 2016
When the reactor coolant system is in high pressure condition such as station black out (SBO) accidents, the cooling water must be supplied smoothly by gravity force without active components. In accordance with these requirements, the Hybrid Safety Injection Tank (Hybrid SIT) system is suggested by the Korea Atomic Energy Research Institute (KAERI) for the passive emergency core cooling system (PECCS). The Hybrid SIT and pressurizer is connected to the pressure balancing line (PBL) to cope with high pressure accident scenarios. In order to consider the thermal-hydraulic phenomena of the Hybrid SIT, the heat transfer characteristics inside the Hybrid SIT should be evaluated. In this study, a heat transfer method using experimental data has been proposed for the quantification of heat and condensation ratio. From the analytical investigations, it is found that the wall heat transfer is the most dominant mechanism for the present Hybrid SIT.
Cited by 0 works.