遠心力、コリオリ力、浮力が同時に作用する管内流の特性

Hiroshi Ishigaki, Munekazu Mochizuki, 石垣 博 et al. · JAXA Repository (JAXA) · 2000

The fluid flowing in rotating heated curved pipes is subjected to three body forces:centrifugal, Coriolis and buoyant forces. Fully developed laminar flow in heated rotating coiled pipes is investigated through similarity arguments and computational studies. Similarity arguments for small and large buoyancy clarify that the characteristics of flow and heat transfer in loosely coiled, rotating heated pipes are governed by five parameters: the Dean number K(sub LC), a body force ratio F, the Rossby number R(sub 0), the Prandtl number P(sub r) and a buoyancy parameter B or a thermal parameter K(sub LB). Detailed structures of velocity and temperature fields are shown for wide range of these parameters. By using a composite parameter K(sub LCR), computed results on the friction factor and the Nusselt number are also shown for a wide parameter space.

Cited by 0 works.

Authors