열화상 측정법과 열류량 측정법을 이용한 기존 외벽체의 열관류율 및 민감도 분석

최두성, 고명진 · 한국생활환경학회지 · 2017

This paper reviewed the validity of IRT from the comparison·analysis of U-value and HFM results of apartments in Korea, which have been calculated using IRT, and presents the evaluation solution for thermal insulation performance that can consider the main environmental factors. Side walls of 3 apartments that were constructed in 10- year intervals from one another, were selected as subjects of measurement. The subjects’ environmental impact of surroundings and measurement device’s errors were considered for analysis. In result, it is evaluated that there is validity of ±20% error between IRT and HFM measurement methods when reflected temperature is at ±1.0oC range of air temperature and emissivity is at ±0.2 range.