한국형발사체 발사대시스템 지상장비제어계 필드 인터페이스

문경록, 안재철, 정일형 et al. · 한국추진공학회 학술대회논문집 · 2016

Technological Equipment Automated Control System (TEACS) has an electrical interface with the major control object, Fuel Ground Support Equipment (FGSE). The connecting part between the two is referred to as the field interface. But an electrical joint may cause a signal error, electromagnetic interference, or a spark at any time depending on the integrity or soundness of its connection. Thus the field interface can be a source of fire around launcher or operation failure. The system developer of TEACS should make a construction based on accurate understanding of the field interface. In this paper, we introduce the field interface design contents about TEACS in KSLV-II Launch Complex.

Cited by 0 works.