초고층 건물을 위한 다이아그리드 노드의 내진성능 평가
정인용, 김상대 · 대한건축학회 춘계 우수졸업논문전 수상논문 개요집 · 2010
This project was conducted to evaluate the structural efficiency of diagrid nodes which resists the seismic or wind loads. The study was experimented with four types of specimens, MA/MB Type and PA/PB Type. To describe the diagrid structural system subjected to lateral load, tensile force was applied to one diagrid brace member while compression force was applied to the other diagrid brace member. Parameters are welding method and design detail. The experiment was measured for initial stiffness, yielding strength and absorbed energy in each parameter. Various results were come out on each specimen and the major fracture was derived from an extra moment. MB Type and PB Type have higher yielding strengths and energy absorbtion compared with MA Type. Specimens which were fabricated with partial penetration welding method have tendency of higher energy absorbtion. However, it is about to be brittle so that partial penetration welding method should be used with carefulness.
Cited by 0 works.