한외여과에서의 물질전달에 대한 난류촉진물체의 영향
오원석, 박함용, 임교빈 et al. · Membrane Journal · 1994
The GR51PP(MWCO 50,000) and GR40PP(MWCO 100,000) membranes manufactured by DDS were used in ultrafiltration of dextran(Mw. : 500,000) solution in flat plate ultrafiltration cell filled with various types of turbulence promoters. The flux improvement by using turbulence promoter was higher in laminar flow region than in turbulent flow region. The maximum improvements of permeate flux were foud as 112% and 50% I laminar flow region and turbulent flow region, respectively. Also, the solute rejection of the ultrafiltration membrane was improved by turbulence promoters and its effect was significant in the high transmembrane pressure and laminar flow region. The smaller the spacer mesh size was used, the higher the flux improved, but the pressure drop in ultrafiltration cell also increased. In laminar flow region, pressure drop by the spacer was negligible, but in turbulent flow region it changed significantly depending upon the mesh size of the spacer and therefore, its mesh size must be baken into account in the design of the process. The predicted results of the modified mass transfer correlation had better agreement with experimental results than those of unmodified one, The modified mass transfer correlations for laminar and turbulent flow region are shown as follow. Nsh}=0.151(NRe})0.199}(NSc})0.22}(NScm})0.197};(625
Cited by 0 works.