산화제 과잉 예연소기용 분사기 설계 및 수류시험 결과
소윤석, 우성필, 이광진 et al. · 한국추진공학회 학술대회논문집 · 2016
This paper is described for results of cold flow test and design of injectors for oxidizer-rich preburner applied with 9tonf-class staged combustion engine cycle. The 3 types of coaxial swirl injectors are designed and manufactured. The diameters of fuel tangential hole are same with 0.7 mm. The diameters of oxidizer tangential hole are difference because of momentum ratio which is Gox oxidizer momentum occurred by combustion from mixing of fuel and oxidizer in the injector chamber and Lox oxidizer momentum from cooling channel. It will be confirmed by the powerpack and combustion test of oxidizer rich preburner in later. The results of cold flow test, the fuel flowrate is proper for differential pressure at design point but the oxidizer flowrate is over for differential pressure at design point.
Cited by 0 works.