양방향 제어효과를 가지는 액체 댐퍼
민경원, 김동익, 박지훈 et al. · 한국지진공학회 추계워크샵 발표논문집 · 2011
This study presents a Tuned Liquid Damper for controlling bidirectional wind responses. Generally, wind responses have two axial directions; along and across wind directions. In this reason, two dampers are usually needed to reduce wind responses of tall buildings. Because of economic inefficiency and restriction of space, it is almost impossible to install two dampers. In this study, proposed damper which is called Bidirectional Tuned Liquid Damper(BTLCD) has the advantage of controlling both responses with a single damper. The damper behaves as a TLCD in a longitudinal direction and a TLD in the other orthogonal direction. This paper conducts experimental verification to confirm its control performance. First, shaking table test is carried out to identify reducing responses by the damper. Shaking table testing results show that BTLCD reduced not only bidirectional responses of a SDOF building but also its torsion responses.