In order to assess shear strength of non-supporting composite basement wall, the research produced three test objects to examine shear performance according to wall thickness, and to compare test results with standard formula. The result demonstrated that the thicker wall improved initial rigidity and shear strength, however, after reaching maximum load, shear strength declined fast. In NS1-C60-W25, displacement-ductility ratio turned out to be small, suggesting that wall thickness affected brittle behavior. The formula that assessed shear strength of composite wall made of steel H-Pile and concrete turned out reliable. Zsutty formula yielded similar result to test outcomes for both cases of effective depths (concrete only; steel H-Pile+concrete). Results of the test and formula calculation showed less gap when steel frame+concrete was considered for effective depth, rather than considering concrete only. Thus, it is assumed that shear strength can be calculated by taking steel frame+concrete into account as effective depth.