코안다 효과를 이용한 평판 슬롯의 막냉각 성능 향상
김기문, 김예지, 곽재수 · The KSFM Journal of Fluid Machinery · 2017
In this study, the Coanda effect inducing bump was applied to improve the film cooling effectiveness on the flat plate with 30° and 45° angled rectangular slots. The slot length to width ratio was 6. A cylindrical cap shaped structure, called Coanda bump, was installed at the exit of the slot to generate Coanda effect. The width and height of the bump was 10.5 mm and 1 mm, respectively. The film cooling effectiveness was measured at the fixed blowing ratio, M=2.0, using pressure sensitive paint (PSP) technique. The mainstream velocity was 10 m/s and the turbulence intensity was about 0.5%. Results showed that the film cooling effectiveness for case of 30° angled slot was higher than that of 45° angled slot. It was found that there was no positive effect of Coanda effect on the overall averaged film cooling effectiveness for the 30° angled slot. On the other hand, for the 45° angled slot, the film cooling effectiveness was improved with the installation of the Coanda bump.