МОРФОЛОГИЧЕСКАЯ ОЦЕНКА ЭФФЕКТИВНОСТИ ЭВЕРТИРОВАННОГО МЕХАНИЧЕСКОГО ШВА, УКРЫТОГО АМНИОТИЧЕСКОЙ МЕМБРАНОЙ, ПРИ РАЗРЫВЕ ТОНКОЙ КИШКИ В УСЛОВИЯХ ЭКСПЕРИМЕНТАЛЬНОГО ПЕРИТОНИТА

Н. В. Завада, O.E. Volkov, С. Н. Рябцева et al. · 2017

We performed an experimental study to compare application of original stappled intestinal suture covered with amniotic membranae and general (standard) intestinal suture methods. Pathogenetic-based blunt abdominal trauma with gydrodynamic stroke intestinal rupture model was used to create each of two conditions: intestinal rupture complicated with 3 hours-last acute peritonitis and intestinal rupture complicated with 24 hours-last acute peritonitis. group 1 – small intestine damage was sutured with a single continuous hand-wound stiches 6–0 (Schmiden’s), which was covered by a single-row Lambert stitches, subgroup 2 – with mechanical suture in the transverse direction by the linear stapler device, than it was covered by a single-row serous Lambert stitches, subgroup 3 – an everted mechanical seam was applied in the transverse direction, which was covered with a patch of cryopreserved amniotic membrane. The experimental animals were crucified after intestinai rupture suturing on the 7th, 14th and 30th days. According to growth of fibrous tissue, both in the joint zone and outside it, tendency to abdominal adhesions it turned out, that proposed method reduces adhesions formation intensity in abdominal cavity.

Cited by 0 works.